Correct installation of the thermal insulation holders

Calculation of the number of DTI in accordance with the norms and requirements of the TKP

Selection of DTI depending on insulation materials and base

Calculation of the number of insulation fasteners

In accordance with the requirements of ТКП 45-3.02-113-2009 и ТКП 45-3.02-114-2009 , thermal insulation slabs are glued to the sub-base over leads or using another method ensuring verticality or specified slope of the surface within the established tolerance.

Glue must be applied to slabs in accordance with the diagrams presented in the design documentation. The area of gluing slabs and the consumption of glue compoung are prescribed dependind on the quality and texture of sub-base in accordance with the requirements of process flow charts.

Fastening of slabs to the sub-base using thermal insulation fasteners must be performed in accordance with the design documentation after glue hardening. For installation of the fastener, cut through thermal insulation and drill a hole in the sub-base. Depth of the hole must be at least 15 mm more than the required depth of embedding of the insulation fasteners.

Exact number of thermal insulation fasteners installed per 1 m2 of the insulated surface is determined in accordance with point 6.10 of TC0CP 45-3.02-113-2009.

При расчете количества ДТИ необходимо учитывать особенности архитектуры здания. При этом количество держателей должно быть увеличено для краевых зон.

Calculation of the number of fasteners must be performed in accordance with architectural features of the building. the number of holders may be increased for end areas. Recommended number of thermal insulation fasteners installed per 1 m2 of the insulated surface 

Building height, m

Internal area of wall plane l, pcs/m2

Edge area from  1,2 to 2,0 m от угла по плоскости стены b, шт/м2

< 8

8-20

> 20

6

6

8

7

8

12

6 шт/м2

8 шт/м2

12 шт/м2

Range of EKT thermal insulation fasteners

DTM-N + GT-MT

Держатель теплоизоляционных материалов (DTM-N) со стальным гвоздем с термо-заглушкой (GT-MT)

DTM-N + GT-P

Держатель теплоизоляционных материалов (DTM-N) с пластмассовым гвоздем (GT-P)

DTM-N + GT-M

Держатель теплоизоляционных материалов (DTM-N) со стальным гвоздем (GT-M)

DTM-UZ + GT-MT

ДТИ с удлиненной распорной зоной (DTM-UZ) со стальным гвоздем с термо-заглушкой (GT-MT)

DTM-UZ + HT-MT 
(заказная позиция)

ДТИ с удлиненной распорной зоной (DTM-UZ) со стальным гвоздем с шестигранной термо-заглушкой (HT-MT)